Issue:
The customer/integrator is having trouble adding Dahua cameras to Contera.
Resolution:
From the Dahua camera webpage:
- Click Setting > Camera > Video.
- Under Main Stream, set Encode Mode to H.264.
- Under Sub Stream1, set Encode Mode to H.264.
- Click Save.
- Click Setting > System > Account > ONVIF User.
- Click Add User and fill in the information
From the Contera NVR:
- Click Setup > Camera > Add cameras.
- Once the auto discover locates the cameras, authenticate using the information from Step 2.
For Dahua multi-sensor cameras, they may need to be added using RTSP instead.
- Click Setup > Camera > Add cameras > Manually add a camera.
- Next to Protocol select RTSP.
- The Dahua RTSP syntax and an example are below:
rtsp:// [USER] : [PASS] @ [ADDRESS] : [RTSP PORT] /cam/realmonitor?channel= [CH] &subtype=[STREAM TYPE]
Dahua Main Stream: rtsp://admin:password@192.168.1.100:554/cam/realmonitor?channel=1&subtype=0
Dahua Sub Stream: rtsp://admin:password@192.168.1.100:554/cam/realmonitor?channel=1&subtype=1
Comments
0 comments
Article is closed for comments.